LA GARD 700 Series Programming

Programming instructions for dormakaba LA GARD 700 Series electronic safe locks.

⚠️ Important Safety Notes

  • Test new codes with door OPEN before closing
  • Write down codes and store outside the safe
  • Change default codes immediately
  • 4 wrong entries = 5-minute lockout
  • Replace 9V batteries annually

Official Documentation

Which Keypad Do You Have?

Model Display Users
700 Basic ❌ No 2
702 ❌ No 30
702D ✅ OLED 30
703-705 ✅ OLED 30-100

700 Basic No Display

6-digit codes, button sequences

Default Codes

Manager

123456
6 digits

Super Master

55555555
8 digits

User

Not Set
Add via Mgr

Open the Lock

  1. Enter 6-digit code
  2. Turn handle within 4 seconds

Change Manager Code

  1. Enter 000000 (six zeros)
  2. Enter current code (default: 123456)
  3. Enter new 6-digit code
  4. Re-enter new code to confirm
  5. Test with door open!

Add a User

  1. Enter Manager code, hold last digit 3 sec
  2. Press 1
  3. Enter new User's 6-digit code
  4. Re-enter to confirm

User Commands

Manager enters code, holds last digit 3 sec, then:

PressAction
1Add/Reinstate User
2Disable User
3Delete User

702 Non-Display # Commands

Multi-user, # command sequences

Default Codes

Master (00)

00-12345678
ID + 8 digits

Manager (01)

01-123456
ID + 6 digits

Users

ID 02-29
Not set

Open the Lock

  1. Press any key to wake
  2. Enter ID + combo (e.g., 01123456)
  3. Press Return (↵)
  4. Turn handle within 3 sec

# Commands

CmdFunction
#50Add User
#52Change Combo
#54Enable/Disable
#56Delete User
#72Time Delay
#25Factory Reset

Change Combo (#52)

Command:
#52 + ID + OldCombo + ID + NewCombo + ID + NewCombo + ↵

Add User (#50)

Command:
#50 + YourID + YourCombo + NewID + NewCombo + 2 + 3 + ↵
2=Standard User | 3=Open+Audit

702D, 703, 704, 705 OLED Display

Menu navigation with display

Default Codes

Master (00)

00-12345678
ID + 8 digits

Manager (01)

01-123456
ID + 6 digits

Users

ID 02+
Not set

Display Buttons

Scroll Select # Back

Open the Lock

  1. Press any key to wake
  2. Enter 2-digit ID (e.g., 01)
  3. Enter 6-digit combo
  4. Turn handle within 3 sec

Menu Paths

Change Combo:

Add User:

Delete User:

Time Delay:

LED & Audio Signals

🟢
Green + beepButton OK
🔴
Red + beepInvalid
🟢🟢🟢
3 greenSuccess
🔴🔴🔴
3 redInvalid code
🔴⏱️
Red/10sLockout
🔋
5 beepsLow battery

Troubleshooting

  • No response: Replace 9V batteries
  • Wrong code: Wait 30 sec. 4 wrong = 5 min lockout
  • Forgot combo: Call Key-En-Lock for safe opening
  • Press # to cancel and start over

Need Help?

We service LA GARD 700 Series locks.

📞 (321) 224-5625

📘 Related

Lock UpgradesSafe Services